DEV-G1 Three Phase Borewell Water Level Controller
DEV-G1 Three Phase Borewell Water Level Controller
Couldn't load pickup availability
VUKAR DEV-G1 is a three phase borewell water level controller with a single float switch, cyclic timer, motor monitoring and protection.
VUKAR DEV-G1 comes from pump control manufacturer Vukar Automation in Rajkot. Compare the listed DEV-G1 controls with your pump task.
Who Should Choose This Model
Choose DEV-G1 for a three phase borewell pump that needs tank-level automation through one cable float switch and cyclic-timer control.
Product and Installation Videos
Monitoring and Control
Protection and control features

High-Brightness Dual Digital Display
Shows three phase voltage, current and other pump parameters during operation.

Fault Display Indication
Shows common motor-fault indications to support troubleshooting.

Motor Fault Counter
Records the number of detected motor faults so recurring conditions can be reviewed.

Motor Run-Time Counter
Records cumulative motor running time for maintenance planning.

Motor-On and Fault Indication
Provides visual indication of motor-running and fault status.

Automatic Water Level Controller
Uses the connected float-switch input to start and stop the pump according to tank level.

Water Level Indicator
Shows the tank-level status used by the controller.

Overvoltage and Undervoltage Protection
Stops the pump when supply voltage moves outside the configured range.

Overload and Dry-Run Protection
Stops the motor during detected overload or dry-run conditions to reduce damage risk.

Phase-Loss and Phase-Sequence Protection
Checks phase availability and sequence before three phase pump operation.

Overload Safety Lockout
Keeps the controller stopped after an overload until a manual reset is completed.
Protection and Automation
Timing and automatic control

Auto-Off Stop Timer
Stops the pump after the configured running duration.

Power-On Auto-Start Timer
Adds a configurable delay before pump start after power returns.

Built-In Auto Switch
Supports automatic pump start when the required supply conditions are available.

Cyclic Timer
Runs repeated ON/OFF cycles according to the configured schedule.

Programmable Dry-Run Restart Timer
Stops the pump on dry run and retries after the configured recovery delay.

Timer Power-Failure Recovery
Restores the programmed timer cycle after a power interruption.
Installation and ownership

Digital Product Registration
Supports digital registration for product and service records.

Protective Enclosure

Technical Support
Technical support is available by WhatsApp and call at +91 63588 96254.

Single Cable Float Switch
Includes a single cable float switch for borewell tank-level control.
Selection and Installation
Use with a compatible three phase borewell pump starter circuit. Have a qualified electrician verify phase sequence and connect the single float switch and motor wiring according to the supplied wiring guide.
Before Ordering
Verify motor rating, wiring and sensor configuration. Review the current Shipping Policy, Refund Policy and Contact page.
FAQ
Which application is DEV-G1 for?
Choose DEV-G1 for a three phase borewell pump that needs tank-level automation through one cable float switch and cyclic-timer control.
Does it include a clock timer?
DEV-G1 uses cyclic timing for repeating ON/OFF operation and has no time-of-day clock timer. For clock scheduling in the same application, compare DEV-G3.
How should the float switch be connected?
Follow the supplied wiring guide and use a qualified electrician.
Compare Related Models
More VUKAR comparisons
Share
Customers are saying

Motor Starter Panel & Protection Devices
View all-
Single Phase Borewell Level Control Panels (BOA) ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Single Phase Borewell Level Control Panels (BOA) options compare ಮಾಡಿ. ಆಯ್ಕೆ...
-
Three Phase Digital Auto Switch for Water Pumps ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Three Phase Digital Auto Switch for Water Pumps options compare ಮಾಡಿ....
-
VUKARನ ಎಲ್ಲಾ Products
ಒಂದೇ listingನಲ್ಲಿ ಪೂರ್ಣ VUKAR catalogue ನೋಡಿ: starter panels, auto switches, water level...
-
Three Phase Borewell DOL Panels with Timer (TPM) ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Three Phase Borewell DOL Panels with Timer (TPM) options compare ಮಾಡಿ....
Blog posts
View all-
DOL Starter Coil Voltage: ಸರಿಯಾದ Replacement Co...
Mohit Vekariaಮೂರು ನಿಜವಾದ TeSys D part codes ಮೂಲಕ coil supply ಅರ್ಥಮಾಡಿಕೊಂಡು replacement ವಿವರ ಸಿದ್ಧಪಡಿಸಿ.
DOL Starter Coil Voltage: ಸರಿಯಾದ Replacement Co...
Mohit Vekariaಮೂರು ನಿಜವಾದ TeSys D part codes ಮೂಲಕ coil supply ಅರ್ಥಮಾಡಿಕೊಂಡು replacement ವಿವರ ಸಿದ್ಧಪಡಿಸಿ.
-
Forward/Reverse DOL Starter: Interlocks ಹೇಗೆ ಕೆ...
Mohit VekariaConveyor ಉದಾಹರಣೆಯ ಮೂಲಕ direction command, feedback ಮತ್ತು ನಿಜವಾದ ಚಲನೆಯನ್ನು ಬೇರ್ಪಡಿಸಿ.
Forward/Reverse DOL Starter: Interlocks ಹೇಗೆ ಕೆ...
Mohit VekariaConveyor ಉದಾಹರಣೆಯ ಮೂಲಕ direction command, feedback ಮತ್ತು ನಿಜವಾದ ಚಲನೆಯನ್ನು ಬೇರ್ಪಡಿಸಿ.
-
DOL Starter Overload Relay Range Chart: ಸರಿಯಾದ ...
Mohit Vekaria9.2 A ಉದಾಹರಣೆ, ಹೊಂದುವ relay ranges ಮತ್ತು ಸರಬರಾಜುದಾರರಿಗೆ ಬೇಕಾದ ವಿವರಗಳು.
DOL Starter Overload Relay Range Chart: ಸರಿಯಾದ ...
Mohit Vekaria9.2 A ಉದಾಹರಣೆ, ಹೊಂದುವ relay ranges ಮತ್ತು ಸರಬರಾಜುದಾರರಿಗೆ ಬೇಕಾದ ವಿವರಗಳು.
-
Timer ಇರುವ DOL Starter: Timed Stop, Run/Rest ಅಥ...
Mohit Vekariaಮೂರು pump ಉದಾಹರಣೆಗಳಿಂದ start ಮತ್ತು stop ಸ್ಥಿತಿಯನ್ನು ಬರೆದು ಸರಿಯಾದ timer ಆಯ್ಕೆ ಮಾಡಿ.
Timer ಇರುವ DOL Starter: Timed Stop, Run/Rest ಅಥ...
Mohit Vekariaಮೂರು pump ಉದಾಹರಣೆಗಳಿಂದ start ಮತ್ತು stop ಸ್ಥಿತಿಯನ್ನು ಬರೆದು ಸರಿಯಾದ timer ಆಯ್ಕೆ ಮಾಡಿ.
Blog posts
View all-
WhatsApp ಮೂಲಕ VUKAR ವಾರಂಟಿ ನೋಂದಣಿ
ಡಿಜಿಟಲ್ ಮೀಟರ್ನಲ್ಲಿ WRT ತಲುಪಿ, 3 ಅಂಕಿಯ ಕೋಡ್ ಅಥವಾ ಫೋಟೋವನ್ನು WhatsApp ಮೂಲಕ ಕಳುಹಿಸಿ. ಪಾಸ್ವರ್ಡ್ ನಮೂದಿಸಿ ಸಾಧನವನ್ನು ಮತ್ತೆ ಆನ್ ಮಾಡಿ.
WhatsApp ಮೂಲಕ VUKAR ವಾರಂಟಿ ನೋಂದಣಿ
ಡಿಜಿಟಲ್ ಮೀಟರ್ನಲ್ಲಿ WRT ತಲುಪಿ, 3 ಅಂಕಿಯ ಕೋಡ್ ಅಥವಾ ಫೋಟೋವನ್ನು WhatsApp ಮೂಲಕ ಕಳುಹಿಸಿ. ಪಾಸ್ವರ್ಡ್ ನಮೂದಿಸಿ ಸಾಧನವನ್ನು ಮತ್ತೆ ಆನ್ ಮಾಡಿ.
-
Relay ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ: Interactive Pump Sta...
Interactive relay walkthroughನಲ್ಲಿ pump start requestನ ಮಾರ್ಗ ನೋಡಿ ಮತ್ತು ನಾಲ್ಕು ಸಾಮಾನ್ಯ faults control sequence ಅನ್ನು ಎಲ್ಲಿ ನಿಲ್ಲಿಸುತ್ತವೆ ಎಂದು ತಿಳಿಯಿರಿ.
Relay ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ: Interactive Pump Sta...
Interactive relay walkthroughನಲ್ಲಿ pump start requestನ ಮಾರ್ಗ ನೋಡಿ ಮತ್ತು ನಾಲ್ಕು ಸಾಮಾನ್ಯ faults control sequence ಅನ್ನು ಎಲ್ಲಿ ನಿಲ್ಲಿಸುತ್ತವೆ ಎಂದು ತಿಳಿಯಿರಿ.
-
Megger Test: ಉದ್ದೇಶ, ವಿಧಾನ ಮತ್ತು Insulation Res...
Motor insulation resistance ತಿಳಿಯಿರಿ. ಕಡಿಮೆಯಾಗುವ megohm reading ಏನು ಸೂಚಿಸಬಹುದು ಮತ್ತು test reportನಲ್ಲಿ ಯಾವ ಮಾಹಿತಿ ಕೇಳಬೇಕು ಎಂದು ನೋಡಿ.
Megger Test: ಉದ್ದೇಶ, ವಿಧಾನ ಮತ್ತು Insulation Res...
Motor insulation resistance ತಿಳಿಯಿರಿ. ಕಡಿಮೆಯಾಗುವ megohm reading ಏನು ಸೂಚಿಸಬಹುದು ಮತ್ತು test reportನಲ್ಲಿ ಯಾವ ಮಾಹಿತಿ ಕೇಳಬೇಕು ಎಂದು ನೋಡಿ.
-
RCBO Full Form: ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ ಮತ್ತು RCCBಗ...
RCBO ಏನನ್ನು ರಕ್ಷಿಸುತ್ತದೆ, markings ಹೇಗೆ ಓದಬೇಕು ಮತ್ತು RCCB ಹಾಗೂ ಪ್ರತ್ಯೇಕ MCBಗಳ ಜೊತೆ ಹೋಲಿಕೆ ಹೇಗಿದೆ ಎಂದು ನೋಡಿ.
RCBO Full Form: ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ ಮತ್ತು RCCBಗ...
RCBO ಏನನ್ನು ರಕ್ಷಿಸುತ್ತದೆ, markings ಹೇಗೆ ಓದಬೇಕು ಮತ್ತು RCCB ಹಾಗೂ ಪ್ರತ್ಯೇಕ MCBಗಳ ಜೊತೆ ಹೋಲಿಕೆ ಹೇಗಿದೆ ಎಂದು ನೋಡಿ.