Single Phase Automatic Openwell Starter with Level Controller & MCB, 0.5–3 HP (OPA-H)
Single Phase Automatic Openwell Starter with Level Controller & MCB, 0.5–3 HP (OPA-H)
Couldn't load pickup availability
VUKAR OPA-H is a single phase automatic openwell starter for 0.5–3 HP pumps. It combines a Water Level Controller, included cable float switch, Water Level Indicator, Cyclic Timer, inbuilt MCB and motor protection. The pump starts and stops automatically according to the connected tank-level sensor.
VUKAR OPA-H comes from pump control manufacturer Vukar Automation in Rajkot. Use the OPA-H code when requesting product support.
Display and everyday operation

High-brightness dual display
Shows supply voltage, motor current, timer values and fault information for routine monitoring.

Fault display
Shows fault indications to help identify common pump and supply problems.

Motor fault counter
Records the number of motor trips so recurring faults can be reviewed.

Total run-time counter
Tracks cumulative motor operating hours for maintenance records.

Motor ON and fault indication
Shows whether the pump is running and provides a visible fault indication.

Water Level Controller
Automatically starts and stops the pump according to the connected tank-level sensor.
Protection and control features

Water Level Indicator
Shows the connected tank's full or empty status.

Overvoltage and undervoltage protection
Stops the motor when supply voltage moves outside the user-set limits.

Overload and dry-run protection
Stops the pump when motor current indicates overload or dry-run conditions, using user-set thresholds.

Overload safety lockout
Requires a manual reset after the configured overload lockout condition.
Timing and automatic control

Auto-off stop timer
Stops the motor after the user-set run duration.

Power-on start delay
Delays motor restart after the electricity supply returns.

Inbuilt Auto Switch
Can start the pump automatically after healthy power returns, according to the configured settings.

Cyclic Timer
Runs repeated ON and OFF cycles using user-set durations.

Dry-run auto-restart timer
After a dry-run trip, waits for the user-set interval before attempting a restart.

Power-failure recovery
Retains the configured timer operation after a power interruption.
Installation and ownership

Digital product registration
Lets the buyer register the product and keep the purchase record linked to support and warranty service.

Serviceable internal wiring
Uses lug-based FRLS internal wiring on terminals so internal parts can be serviced or replaced.

440 V motor run capacitor
Includes a 440 V run capacitor selected for the corresponding motor rating.

Inbuilt MCB
Provides short-circuit protection for the starter panel's incoming circuit.

Spare-parts support
Replacement control-panel parts can be sourced for service; confirm the exact compatible part before purchase.

Protective enclosure
The metal enclosure shields the internal control components. Installation and earthing must be completed by a qualified electrician.

Powder-coated metal enclosure
The powder-coated metal cabinet protects the internal components during normal installed use.

Technical support
For installation, fault codes and warranty support, call or WhatsApp +91 63588 96254.

Cable float switch included
A cable float switch is supplied for automatic tank-level sensing.
Who should choose OPA-H?
- 0.5–3 HP single phase openwell pumps
- Automatic tank-level start and stop
- Cyclic Timer operation with motor protection
Warranty, shipping and support
A one-year parts replacement warranty applies to manufacturing defects. Requests for a defective, damaged, wrong or not-as-described product must be raised within seven days of delivery; change-of-mind returns are not offered. Shipping is free across India. Orders dispatch in 0–1 working day and delivery is normally expected 1–5 working days from the order date, subject to courier or postal service. An optional paid three-year extended warranty is available.
Frequently asked questions
Does OPA-H automatically start and stop the pump by tank level?
Yes. The connected cable float switch senses tank level, and the Water Level Controller operates the pump according to its configured logic.
Is the cable float switch included?
Yes. A cable float switch is supplied for automatic tank-level sensing.
Is an MCB included?
Yes. OPA-H includes an inbuilt MCB for short-circuit protection of the starter panel's incoming circuit.
How should it be installed?
Have a qualified electrician verify the motor rating, float switch, capacitor, protection settings, earthing and power wiring before operation.
Who handles order and delivery support?
Call or WhatsApp +91 95121 72271, or email online@vukar.com. For technical support, contact +91 63588 96254.
Compare VUKAR models before you buy
Product videos and selection guidance: OPA-H product videos.
VUKAR OPA-H Openwell Starter Panel: Installation and Water-Level Settings
Share
Customers are saying

Motor Starter Panel & Protection Devices
View all-
Single Phase Borewell Level Control Panels (BOA) ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Single Phase Borewell Level Control Panels (BOA) options compare ಮಾಡಿ. ಆಯ್ಕೆ...
-
Three Phase Digital Auto Switch for Water Pumps ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Three Phase Digital Auto Switch for Water Pumps options compare ಮಾಡಿ....
-
VUKARನ ಎಲ್ಲಾ Products
ಒಂದೇ listingನಲ್ಲಿ ಪೂರ್ಣ VUKAR catalogue ನೋಡಿ: starter panels, auto switches, water level...
-
Three Phase Borewell DOL Panels with Timer (TPM) ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Three Phase Borewell DOL Panels with Timer (TPM) options compare ಮಾಡಿ....
Blog posts
View all-
TPO-H ಟ್ಯಾಂಕ್ ತುಂಬುತ್ತಿಲ್ಲ? Float signal, ಮೋಟರ್...
Mohit VekariaTPO-H ಟ್ಯಾಂಕ್ ತುಂಬುತ್ತಿಲ್ಲವೆಂದರೆ ಮೊದಲು ಎರಡು level ದಾಖಲಿಸಿ.
TPO-H ಟ್ಯಾಂಕ್ ತುಂಬುತ್ತಿಲ್ಲ? Float signal, ಮೋಟರ್...
Mohit VekariaTPO-H ಟ್ಯಾಂಕ್ ತುಂಬುತ್ತಿಲ್ಲವೆಂದರೆ ಮೊದಲು ಎರಡು level ದಾಖಲಿಸಿ.
-
TPM-W ಟ್ಯಾಂಕ್ level display ತಪ್ಪು? Float indica...
Mohit VekariaTPM-W tank level display ತಪ್ಪಾಗಿ ಕಂಡರೆ ನಿಜವಾದ level, float indicator ಮತ್ತು pumpನ RUN ಅಥವಾ rest ಬರೆಯಿರಿ.
TPM-W ಟ್ಯಾಂಕ್ level display ತಪ್ಪು? Float indica...
Mohit VekariaTPM-W tank level display ತಪ್ಪಾಗಿ ಕಂಡರೆ ನಿಜವಾದ level, float indicator ಮತ್ತು pumpನ RUN ಅಥವಾ rest ಬರೆಯಿರಿ.
-
TPM-V ಟ್ಯಾಂಕ್ level display ತಪ್ಪು? Float indica...
Mohit VekariaTPM-V tank level display ತಪ್ಪಾಗಿ ಕಂಡರೆ ನಿಜವಾದ ನೀರಿನ ಮಟ್ಟ ಮತ್ತು indicator ಅನ್ನು ಒಂದೇ ಹೊತ್ತಿನಲ್ಲಿ ಬರೆಯಿರಿ.
TPM-V ಟ್ಯಾಂಕ್ level display ತಪ್ಪು? Float indica...
Mohit VekariaTPM-V tank level display ತಪ್ಪಾಗಿ ಕಂಡರೆ ನಿಜವಾದ ನೀರಿನ ಮಟ್ಟ ಮತ್ತು indicator ಅನ್ನು ಒಂದೇ ಹೊತ್ತಿನಲ್ಲಿ ಬರೆಯಿರಿ.
-
TPM-T daily run time ಬೇಗ ನಿಲ್ಲುತ್ತದೆ? ವಿದ್ಯುತ್ ...
Mohit VekariaTPM-T daily run time ಬೇಗ ನಿಂತಂತೆ ಕಂಡರೆ ಮೋಟರ್ ನಿಜವಾಗಿ ಓಡಿದ ನಿಮಿಷಗಳು ಮತ್ತು ವಿದ್ಯುತ್ ಮರಳಿದ ಸಮಯ ದಾಖಲಿಸಿ.
TPM-T daily run time ಬೇಗ ನಿಲ್ಲುತ್ತದೆ? ವಿದ್ಯುತ್ ...
Mohit VekariaTPM-T daily run time ಬೇಗ ನಿಂತಂತೆ ಕಂಡರೆ ಮೋಟರ್ ನಿಜವಾಗಿ ಓಡಿದ ನಿಮಿಷಗಳು ಮತ್ತು ವಿದ್ಯುತ್ ಮರಳಿದ ಸಮಯ ದಾಖಲಿಸಿ.
Blog posts
View all-
WhatsApp ಮೂಲಕ VUKAR ವಾರಂಟಿ ನೋಂದಣಿ
ಡಿಜಿಟಲ್ ಮೀಟರ್ನಲ್ಲಿ WRT ತಲುಪಿ, 3 ಅಂಕಿಯ ಕೋಡ್ ಅಥವಾ ಫೋಟೋವನ್ನು WhatsApp ಮೂಲಕ ಕಳುಹಿಸಿ. ಪಾಸ್ವರ್ಡ್ ನಮೂದಿಸಿ ಸಾಧನವನ್ನು ಮತ್ತೆ ಆನ್ ಮಾಡಿ.
WhatsApp ಮೂಲಕ VUKAR ವಾರಂಟಿ ನೋಂದಣಿ
ಡಿಜಿಟಲ್ ಮೀಟರ್ನಲ್ಲಿ WRT ತಲುಪಿ, 3 ಅಂಕಿಯ ಕೋಡ್ ಅಥವಾ ಫೋಟೋವನ್ನು WhatsApp ಮೂಲಕ ಕಳುಹಿಸಿ. ಪಾಸ್ವರ್ಡ್ ನಮೂದಿಸಿ ಸಾಧನವನ್ನು ಮತ್ತೆ ಆನ್ ಮಾಡಿ.
-
Relay ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ: Interactive Pump Sta...
Interactive relay walkthroughನಲ್ಲಿ pump start requestನ ಮಾರ್ಗ ನೋಡಿ ಮತ್ತು ನಾಲ್ಕು ಸಾಮಾನ್ಯ faults control sequence ಅನ್ನು ಎಲ್ಲಿ ನಿಲ್ಲಿಸುತ್ತವೆ ಎಂದು ತಿಳಿಯಿರಿ.
Relay ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ: Interactive Pump Sta...
Interactive relay walkthroughನಲ್ಲಿ pump start requestನ ಮಾರ್ಗ ನೋಡಿ ಮತ್ತು ನಾಲ್ಕು ಸಾಮಾನ್ಯ faults control sequence ಅನ್ನು ಎಲ್ಲಿ ನಿಲ್ಲಿಸುತ್ತವೆ ಎಂದು ತಿಳಿಯಿರಿ.
-
Megger Test: ಉದ್ದೇಶ, ವಿಧಾನ ಮತ್ತು Insulation Res...
Motor insulation resistance ತಿಳಿಯಿರಿ. ಕಡಿಮೆಯಾಗುವ megohm reading ಏನು ಸೂಚಿಸಬಹುದು ಮತ್ತು test reportನಲ್ಲಿ ಯಾವ ಮಾಹಿತಿ ಕೇಳಬೇಕು ಎಂದು ನೋಡಿ.
Megger Test: ಉದ್ದೇಶ, ವಿಧಾನ ಮತ್ತು Insulation Res...
Motor insulation resistance ತಿಳಿಯಿರಿ. ಕಡಿಮೆಯಾಗುವ megohm reading ಏನು ಸೂಚಿಸಬಹುದು ಮತ್ತು test reportನಲ್ಲಿ ಯಾವ ಮಾಹಿತಿ ಕೇಳಬೇಕು ಎಂದು ನೋಡಿ.
-
RCBO Full Form: ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ ಮತ್ತು RCCBಗ...
RCBO ಏನನ್ನು ರಕ್ಷಿಸುತ್ತದೆ, markings ಹೇಗೆ ಓದಬೇಕು ಮತ್ತು RCCB ಹಾಗೂ ಪ್ರತ್ಯೇಕ MCBಗಳ ಜೊತೆ ಹೋಲಿಕೆ ಹೇಗಿದೆ ಎಂದು ನೋಡಿ.
RCBO Full Form: ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ ಮತ್ತು RCCBಗ...
RCBO ಏನನ್ನು ರಕ್ಷಿಸುತ್ತದೆ, markings ಹೇಗೆ ಓದಬೇಕು ಮತ್ತು RCCB ಹಾಗೂ ಪ್ರತ್ಯೇಕ MCBಗಳ ಜೊತೆ ಹೋಲಿಕೆ ಹೇಗಿದೆ ಎಂದು ನೋಡಿ.