Single Phase Digital Openwell / Borewell Starter Panel with Motor Safety, Motor Auto Off / Stop Timer, Water Level Indicator & MCB (BOM-W)
Single Phase Digital Openwell / Borewell Starter Panel with Motor Safety, Motor Auto Off / Stop Timer, Water Level Indicator & MCB (BOM-W)
Couldn't load pickup availability
BOM-W is a single phase borewell/openwell motor starter panel for 0.5–3 HP pumps. Its defining function is water level indicator, auto-off stop timer and inbuilt MCB. Select the exact HP variant only after matching the pump rating and operating current.
VUKAR BOM-W comes from pump control manufacturer Vukar Automation in Rajkot. Compare the listed BOM-W controls with your pump task.
Who should choose BOM-W?
Choose BOM-W when tank-level indication, timed stopping and an inbuilt MCB are all required in one starter panel.
Model-specific functions
- Water Level Indicator gives visible tank-status information from the connected float switch.
- Auto-Off Stop Timer stops the pump after the duration set on the panel.
- Inbuilt MCB provides short-circuit protection for the panel circuit; cable float switch is included.
Motor protection and monitoring
- Overvoltage and undervoltage protection disconnects the motor when supply voltage moves outside the configured limits.
- Overload and dry-run protection stops the pump when the configured current conditions indicate excess load or loss of water.
- Overload Safety Lockout, Power-On Auto-Start Timer and Programmable Dry-Run Auto-Restart Timer support controlled recovery after a fault or power interruption.
- Motor ON indication, fault display, fault counter and run-time counter provide operating information on the panel.
Product feature reference
Protection and control features

BOM-W: High brightness dual digital display on a single phase panel

BOM-W: Fault display indication showing motor error codes on the panel
BOM-W: Fault display indication showing motor error codes on the panel
BOM-W: Motor fault counter logging and displaying the number of trips
BOM-W: Motor fault counter logging and displaying the number of tripsTiming and automatic control

BOM-W: Motor run time counter logging cumulative pump operating hours
BOM-W: Motor run time counter logging cumulative pump operating hours
BOM-W: Motor on indication confirming the pump is currently running
BOM-W: Motor on indication confirming the pump is currently running
BOM-W: Water level indicator giving visual confirmation of tank status
BOM-W: Water level indicator giving visual confirmation of tank status
BOM-W: Overvoltage and undervoltage protection keeping the motor in safe limits
BOM-W: Overvoltage and undervoltage protection keeping the motor in safe limits
BOM-W: Dry run protection cutting power when the water source runs dry
BOM-W: Dry run protection cutting power when the water source runs dry
BOM-W: Auto off stop timer switching the motor off after a set duration
BOM-W: Auto off stop timer switching the motor off after a set durationInstallation and ownership

BOM-W: Panel internals with ISI marked copper wiring on heavy duty lugs
BOM-W: Panel internals with ISI marked copper wiring on heavy duty lugs
BOM-W: Built in 440 V motor run capacitor for stable starting
BOM-W: Built in 440 V motor run capacitor for stable starting
BOM-W: Inbuilt MCB giving short circuit protection in the panel
BOM-W: Inbuilt MCB giving short circuit protection in the panel
BOM-W: Powder coated metal enclosure protecting the panel internals
BOM-W: Powder coated metal enclosure protecting the panel internals
BOM-W: Cable float switch included for automatic tank level sensing
BOM-W: Cable float switch included for automatic tank level sensingInstallation and selection
- Use only with a compatible single phase borewell or openwell pump within the selected 0.5–3 HP variant range.
- Match the variant to the pump nameplate HP and current; protection settings must be configured for the actual motor.
- Installation, earthing, capacitor connections and sensor wiring should be completed by a qualified electrician.
- Tank sensor or float-switch positioning must be tested before automatic operation.
Warranty, delivery and support
- Warranty: 1 year when purchased from this website.
- Dispatch: 0–1 working day. Expected delivery: 1–5 working days from the order date across India.
- Shipping: free across India.
- Technical support: WhatsApp or call +91 63588 96254.
- To order by phone, send your name, address, contact number, PIN code and model to +91 95121 72271.
Frequently asked questions
Which pumps does BOM-W suit?
Select the matching 0.5–3 HP variant for a single phase borewell or openwell pump. Match the pump nameplate HP and current, and have a qualified electrician verify the wiring and capacitor requirements before installation.
Does BOM-W include automatic tank-level control?
No automatic tank-level control is claimed for this model. It includes tank-level indication through the supplied cable float switch.
Product videos and selection guidance: Water-level indicator videos.
VUKAR BOM-W Borewell Starter Panel: Installation and Auto-Off Timer Settings
Share
Customers are saying

Motor Starter Panel & Protection Devices
View all-
Single Phase Borewell Level Control Panels (BOA) ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Single Phase Borewell Level Control Panels (BOA) options compare ಮಾಡಿ. ಆಯ್ಕೆ...
-
Three Phase Digital Auto Switch for Water Pumps ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Three Phase Digital Auto Switch for Water Pumps options compare ಮಾಡಿ....
-
VUKARನ ಎಲ್ಲಾ Products
ಒಂದೇ listingನಲ್ಲಿ ಪೂರ್ಣ VUKAR catalogue ನೋಡಿ: starter panels, auto switches, water level...
-
Three Phase Borewell DOL Panels with Timer (TPM) ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Three Phase Borewell DOL Panels with Timer (TPM) options compare ಮಾಡಿ....
Blog posts
View all-
Start ಬಟನ್ ಬಿಟ್ಟ ಕೂಡಲೇ DOL Starter ಏಕೆ ನಿಲ್ಲುತ್...
Mohit VekariaStart release ಮತ್ತು ತಡವಾದ trip ನಡುವಿನ ವ್ಯತ್ಯಾಸವನ್ನು ದಾಖಲಿಸಲು ಪ್ರಾಯೋಗಿಕ ಮಾರ್ಗದರ್ಶಿ.
Start ಬಟನ್ ಬಿಟ್ಟ ಕೂಡಲೇ DOL Starter ಏಕೆ ನಿಲ್ಲುತ್...
Mohit VekariaStart release ಮತ್ತು ತಡವಾದ trip ನಡುವಿನ ವ್ಯತ್ಯಾಸವನ್ನು ದಾಖಲಿಸಲು ಪ್ರಾಯೋಗಿಕ ಮಾರ್ಗದರ್ಶಿ.
-
Start ಒತ್ತಿದಾಗ DOL Starter ಕ್ಲಿಕ್ ಮಾಡದಿರುವುದು ಏಕೆ?
Mohit Vekariaಮುಚ್ಚಿದ ಪ್ಯಾನೆಲ್ನಿಂದ ಕಾಣುವ ಮಾಹಿತಿಯನ್ನು ಸಂಗ್ರಹಿಸಿ control circuit ಪರಿಶೀಲನೆಗೆ ತಂತ್ರಜ್ಞರಿಗೆ ಕೊಡಿ.
Start ಒತ್ತಿದಾಗ DOL Starter ಕ್ಲಿಕ್ ಮಾಡದಿರುವುದು ಏಕೆ?
Mohit Vekariaಮುಚ್ಚಿದ ಪ್ಯಾನೆಲ್ನಿಂದ ಕಾಣುವ ಮಾಹಿತಿಯನ್ನು ಸಂಗ್ರಹಿಸಿ control circuit ಪರಿಶೀಲನೆಗೆ ತಂತ್ರಜ್ಞರಿಗೆ ಕೊಡಿ.
-
DOL Starter Coil Voltage: ಸರಿಯಾದ Replacement Co...
Mohit Vekariaಮೂರು ನಿಜವಾದ TeSys D part codes ಮೂಲಕ coil supply ಅರ್ಥಮಾಡಿಕೊಂಡು replacement ವಿವರ ಸಿದ್ಧಪಡಿಸಿ.
DOL Starter Coil Voltage: ಸರಿಯಾದ Replacement Co...
Mohit Vekariaಮೂರು ನಿಜವಾದ TeSys D part codes ಮೂಲಕ coil supply ಅರ್ಥಮಾಡಿಕೊಂಡು replacement ವಿವರ ಸಿದ್ಧಪಡಿಸಿ.
-
Forward/Reverse DOL Starter: Interlocks ಹೇಗೆ ಕೆ...
Mohit VekariaConveyor ಉದಾಹರಣೆಯ ಮೂಲಕ direction command, feedback ಮತ್ತು ನಿಜವಾದ ಚಲನೆಯನ್ನು ಬೇರ್ಪಡಿಸಿ.
Forward/Reverse DOL Starter: Interlocks ಹೇಗೆ ಕೆ...
Mohit VekariaConveyor ಉದಾಹರಣೆಯ ಮೂಲಕ direction command, feedback ಮತ್ತು ನಿಜವಾದ ಚಲನೆಯನ್ನು ಬೇರ್ಪಡಿಸಿ.
Blog posts
View all-
WhatsApp ಮೂಲಕ VUKAR ವಾರಂಟಿ ನೋಂದಣಿ
ಡಿಜಿಟಲ್ ಮೀಟರ್ನಲ್ಲಿ WRT ತಲುಪಿ, 3 ಅಂಕಿಯ ಕೋಡ್ ಅಥವಾ ಫೋಟೋವನ್ನು WhatsApp ಮೂಲಕ ಕಳುಹಿಸಿ. ಪಾಸ್ವರ್ಡ್ ನಮೂದಿಸಿ ಸಾಧನವನ್ನು ಮತ್ತೆ ಆನ್ ಮಾಡಿ.
WhatsApp ಮೂಲಕ VUKAR ವಾರಂಟಿ ನೋಂದಣಿ
ಡಿಜಿಟಲ್ ಮೀಟರ್ನಲ್ಲಿ WRT ತಲುಪಿ, 3 ಅಂಕಿಯ ಕೋಡ್ ಅಥವಾ ಫೋಟೋವನ್ನು WhatsApp ಮೂಲಕ ಕಳುಹಿಸಿ. ಪಾಸ್ವರ್ಡ್ ನಮೂದಿಸಿ ಸಾಧನವನ್ನು ಮತ್ತೆ ಆನ್ ಮಾಡಿ.
-
Relay ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ: Interactive Pump Sta...
Interactive relay walkthroughನಲ್ಲಿ pump start requestನ ಮಾರ್ಗ ನೋಡಿ ಮತ್ತು ನಾಲ್ಕು ಸಾಮಾನ್ಯ faults control sequence ಅನ್ನು ಎಲ್ಲಿ ನಿಲ್ಲಿಸುತ್ತವೆ ಎಂದು ತಿಳಿಯಿರಿ.
Relay ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ: Interactive Pump Sta...
Interactive relay walkthroughನಲ್ಲಿ pump start requestನ ಮಾರ್ಗ ನೋಡಿ ಮತ್ತು ನಾಲ್ಕು ಸಾಮಾನ್ಯ faults control sequence ಅನ್ನು ಎಲ್ಲಿ ನಿಲ್ಲಿಸುತ್ತವೆ ಎಂದು ತಿಳಿಯಿರಿ.
-
Megger Test: ಉದ್ದೇಶ, ವಿಧಾನ ಮತ್ತು Insulation Res...
Motor insulation resistance ತಿಳಿಯಿರಿ. ಕಡಿಮೆಯಾಗುವ megohm reading ಏನು ಸೂಚಿಸಬಹುದು ಮತ್ತು test reportನಲ್ಲಿ ಯಾವ ಮಾಹಿತಿ ಕೇಳಬೇಕು ಎಂದು ನೋಡಿ.
Megger Test: ಉದ್ದೇಶ, ವಿಧಾನ ಮತ್ತು Insulation Res...
Motor insulation resistance ತಿಳಿಯಿರಿ. ಕಡಿಮೆಯಾಗುವ megohm reading ಏನು ಸೂಚಿಸಬಹುದು ಮತ್ತು test reportನಲ್ಲಿ ಯಾವ ಮಾಹಿತಿ ಕೇಳಬೇಕು ಎಂದು ನೋಡಿ.
-
RCBO Full Form: ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ ಮತ್ತು RCCBಗ...
RCBO ಏನನ್ನು ರಕ್ಷಿಸುತ್ತದೆ, markings ಹೇಗೆ ಓದಬೇಕು ಮತ್ತು RCCB ಹಾಗೂ ಪ್ರತ್ಯೇಕ MCBಗಳ ಜೊತೆ ಹೋಲಿಕೆ ಹೇಗಿದೆ ಎಂದು ನೋಡಿ.
RCBO Full Form: ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ ಮತ್ತು RCCBಗ...
RCBO ಏನನ್ನು ರಕ್ಷಿಸುತ್ತದೆ, markings ಹೇಗೆ ಓದಬೇಕು ಮತ್ತು RCCB ಹಾಗೂ ಪ್ರತ್ಯೇಕ MCBಗಳ ಜೊತೆ ಹೋಲಿಕೆ ಹೇಗಿದೆ ಎಂದು ನೋಡಿ.