Single Phase Digital Openwell / Borewell Starter Panel with Motor Safety, Motor Auto Off / Stop Timer & Water Level Indicator (BOM-V)
Single Phase Digital Openwell / Borewell Starter Panel with Motor Safety, Motor Auto Off / Stop Timer & Water Level Indicator (BOM-V)
Couldn't load pickup availability
BOM-V is a single phase borewell/openwell motor starter panel for 0.5–3 HP pumps. Its defining function is water level indicator and auto-off stop timer. Select the exact HP variant only after matching the pump rating and operating current.
VUKAR BOM-V comes from pump control manufacturer Vukar Automation in Rajkot. Ask our sales team about BOM-V supply for your project.
Who should choose BOM-V?
Choose BOM-V when you need protected pump control plus tank-level indication and timed stopping, without an inbuilt MCB.
Model-specific functions
- Water Level Indicator gives visible tank-status information from the connected float switch.
- Auto-Off Stop Timer stops the pump after the duration set on the panel.
- Cable float switch is included for the level-indicator input.
Motor protection and monitoring
- Overvoltage and undervoltage protection disconnects the motor when supply voltage moves outside the configured limits.
- Overload and dry-run protection stops the pump when the configured current conditions indicate excess load or loss of water.
- Overload Safety Lockout, Power-On Auto-Start Timer and Programmable Dry-Run Auto-Restart Timer support controlled recovery after a fault or power interruption.
- Motor ON indication, fault display, fault counter and run-time counter provide operating information on the panel.
Product feature reference
Protection and control features

BOM-V: High brightness dual digital display on a single phase panel

BOM-V: Fault display indication showing motor error codes on the panel
BOM-V: Fault display indication showing motor error codes on the panel
BOM-V: Motor fault counter logging and displaying the number of trips
BOM-V: Motor fault counter logging and displaying the number of tripsTiming and automatic control

BOM-V: Motor run time counter logging cumulative pump operating hours
BOM-V: Motor run time counter logging cumulative pump operating hours
BOM-V: Motor on indication confirming the pump is currently running
BOM-V: Motor on indication confirming the pump is currently running
BOM-V: Water level indicator giving visual confirmation of tank status
BOM-V: Water level indicator giving visual confirmation of tank status
BOM-V: Overvoltage and undervoltage protection keeping the motor in safe limits
BOM-V: Overvoltage and undervoltage protection keeping the motor in safe limits
BOM-V: Dry run protection cutting power when the water source runs dry
BOM-V: Dry run protection cutting power when the water source runs dry
BOM-V: Auto off stop timer switching the motor off after a set duration
BOM-V: Auto off stop timer switching the motor off after a set durationInstallation and ownership

BOM-V: Panel internals with ISI marked copper wiring on heavy duty lugs
BOM-V: Panel internals with ISI marked copper wiring on heavy duty lugs
BOM-V: Built in 440 V motor run capacitor for stable starting
BOM-V: Built in 440 V motor run capacitor for stable starting
BOM-V: Powder coated metal enclosure protecting the panel internals
BOM-V: Powder coated metal enclosure protecting the panel internals
BOM-V: Cable float switch included for automatic tank level sensing
BOM-V: Cable float switch included for automatic tank level sensingInstallation and selection
- Use only with a compatible single phase borewell or openwell pump within the selected 0.5–3 HP variant range.
- Match the variant to the pump nameplate HP and current; protection settings must be configured for the actual motor.
- Installation, earthing, capacitor connections and sensor wiring should be completed by a qualified electrician.
- Tank sensor or float-switch positioning must be tested before automatic operation.
Warranty, delivery and support
- Warranty: 1 year when purchased from this website.
- Dispatch: 0–1 working day. Expected delivery: 1–5 working days from the order date across India.
- Shipping: free across India.
- Technical support: WhatsApp or call +91 63588 96254.
- To order by phone, send your name, address, contact number, PIN code and model to +91 95121 72271.
Frequently asked questions
Which pumps does BOM-V suit?
Select the matching 0.5–3 HP variant for a single phase borewell or openwell pump. Match the pump nameplate HP and current, and have a qualified electrician verify the wiring and capacitor requirements before installation.
Does BOM-V include automatic tank-level control?
No automatic tank-level control is claimed for this model. It includes tank-level indication through the supplied cable float switch.
Product videos and selection guidance: Water-level indicator videos.
VUKAR BOM-V Borewell Starter Panel: Installation and Auto-Off Timer Settings
Share
Customers are saying

Motor Starter Panel & Protection Devices
View all-
Single Phase Borewell Level Control Panels (BOA) ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Single Phase Borewell Level Control Panels (BOA) options compare ಮಾಡಿ. ಆಯ್ಕೆ...
-
Three Phase Digital Auto Switch for Water Pumps ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Three Phase Digital Auto Switch for Water Pumps options compare ಮಾಡಿ....
-
VUKARನ ಎಲ್ಲಾ Products
ಒಂದೇ listingನಲ್ಲಿ ಪೂರ್ಣ VUKAR catalogue ನೋಡಿ: starter panels, auto switches, water level...
-
Three Phase Borewell DOL Panels with Timer (TPM) ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Three Phase Borewell DOL Panels with Timer (TPM) options compare ಮಾಡಿ....
Blog posts
View all-
TPO-H ಟ್ಯಾಂಕ್ ತುಂಬುತ್ತಿಲ್ಲ? Float signal, ಮೋಟರ್...
Mohit VekariaTPO-H ಟ್ಯಾಂಕ್ ತುಂಬುತ್ತಿಲ್ಲವೆಂದರೆ ಮೊದಲು ಎರಡು level ದಾಖಲಿಸಿ.
TPO-H ಟ್ಯಾಂಕ್ ತುಂಬುತ್ತಿಲ್ಲ? Float signal, ಮೋಟರ್...
Mohit VekariaTPO-H ಟ್ಯಾಂಕ್ ತುಂಬುತ್ತಿಲ್ಲವೆಂದರೆ ಮೊದಲು ಎರಡು level ದಾಖಲಿಸಿ.
-
TPM-W ಟ್ಯಾಂಕ್ level display ತಪ್ಪು? Float indica...
Mohit VekariaTPM-W tank level display ತಪ್ಪಾಗಿ ಕಂಡರೆ ನಿಜವಾದ level, float indicator ಮತ್ತು pumpನ RUN ಅಥವಾ rest ಬರೆಯಿರಿ.
TPM-W ಟ್ಯಾಂಕ್ level display ತಪ್ಪು? Float indica...
Mohit VekariaTPM-W tank level display ತಪ್ಪಾಗಿ ಕಂಡರೆ ನಿಜವಾದ level, float indicator ಮತ್ತು pumpನ RUN ಅಥವಾ rest ಬರೆಯಿರಿ.
-
TPM-V ಟ್ಯಾಂಕ್ level display ತಪ್ಪು? Float indica...
Mohit VekariaTPM-V tank level display ತಪ್ಪಾಗಿ ಕಂಡರೆ ನಿಜವಾದ ನೀರಿನ ಮಟ್ಟ ಮತ್ತು indicator ಅನ್ನು ಒಂದೇ ಹೊತ್ತಿನಲ್ಲಿ ಬರೆಯಿರಿ.
TPM-V ಟ್ಯಾಂಕ್ level display ತಪ್ಪು? Float indica...
Mohit VekariaTPM-V tank level display ತಪ್ಪಾಗಿ ಕಂಡರೆ ನಿಜವಾದ ನೀರಿನ ಮಟ್ಟ ಮತ್ತು indicator ಅನ್ನು ಒಂದೇ ಹೊತ್ತಿನಲ್ಲಿ ಬರೆಯಿರಿ.
-
TPM-T daily run time ಬೇಗ ನಿಲ್ಲುತ್ತದೆ? ವಿದ್ಯುತ್ ...
Mohit VekariaTPM-T daily run time ಬೇಗ ನಿಂತಂತೆ ಕಂಡರೆ ಮೋಟರ್ ನಿಜವಾಗಿ ಓಡಿದ ನಿಮಿಷಗಳು ಮತ್ತು ವಿದ್ಯುತ್ ಮರಳಿದ ಸಮಯ ದಾಖಲಿಸಿ.
TPM-T daily run time ಬೇಗ ನಿಲ್ಲುತ್ತದೆ? ವಿದ್ಯುತ್ ...
Mohit VekariaTPM-T daily run time ಬೇಗ ನಿಂತಂತೆ ಕಂಡರೆ ಮೋಟರ್ ನಿಜವಾಗಿ ಓಡಿದ ನಿಮಿಷಗಳು ಮತ್ತು ವಿದ್ಯುತ್ ಮರಳಿದ ಸಮಯ ದಾಖಲಿಸಿ.
Blog posts
View all-
WhatsApp ಮೂಲಕ VUKAR ವಾರಂಟಿ ನೋಂದಣಿ
ಡಿಜಿಟಲ್ ಮೀಟರ್ನಲ್ಲಿ WRT ತಲುಪಿ, 3 ಅಂಕಿಯ ಕೋಡ್ ಅಥವಾ ಫೋಟೋವನ್ನು WhatsApp ಮೂಲಕ ಕಳುಹಿಸಿ. ಪಾಸ್ವರ್ಡ್ ನಮೂದಿಸಿ ಸಾಧನವನ್ನು ಮತ್ತೆ ಆನ್ ಮಾಡಿ.
WhatsApp ಮೂಲಕ VUKAR ವಾರಂಟಿ ನೋಂದಣಿ
ಡಿಜಿಟಲ್ ಮೀಟರ್ನಲ್ಲಿ WRT ತಲುಪಿ, 3 ಅಂಕಿಯ ಕೋಡ್ ಅಥವಾ ಫೋಟೋವನ್ನು WhatsApp ಮೂಲಕ ಕಳುಹಿಸಿ. ಪಾಸ್ವರ್ಡ್ ನಮೂದಿಸಿ ಸಾಧನವನ್ನು ಮತ್ತೆ ಆನ್ ಮಾಡಿ.
-
Relay ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ: Interactive Pump Sta...
Interactive relay walkthroughನಲ್ಲಿ pump start requestನ ಮಾರ್ಗ ನೋಡಿ ಮತ್ತು ನಾಲ್ಕು ಸಾಮಾನ್ಯ faults control sequence ಅನ್ನು ಎಲ್ಲಿ ನಿಲ್ಲಿಸುತ್ತವೆ ಎಂದು ತಿಳಿಯಿರಿ.
Relay ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ: Interactive Pump Sta...
Interactive relay walkthroughನಲ್ಲಿ pump start requestನ ಮಾರ್ಗ ನೋಡಿ ಮತ್ತು ನಾಲ್ಕು ಸಾಮಾನ್ಯ faults control sequence ಅನ್ನು ಎಲ್ಲಿ ನಿಲ್ಲಿಸುತ್ತವೆ ಎಂದು ತಿಳಿಯಿರಿ.
-
Megger Test: ಉದ್ದೇಶ, ವಿಧಾನ ಮತ್ತು Insulation Res...
Motor insulation resistance ತಿಳಿಯಿರಿ. ಕಡಿಮೆಯಾಗುವ megohm reading ಏನು ಸೂಚಿಸಬಹುದು ಮತ್ತು test reportನಲ್ಲಿ ಯಾವ ಮಾಹಿತಿ ಕೇಳಬೇಕು ಎಂದು ನೋಡಿ.
Megger Test: ಉದ್ದೇಶ, ವಿಧಾನ ಮತ್ತು Insulation Res...
Motor insulation resistance ತಿಳಿಯಿರಿ. ಕಡಿಮೆಯಾಗುವ megohm reading ಏನು ಸೂಚಿಸಬಹುದು ಮತ್ತು test reportನಲ್ಲಿ ಯಾವ ಮಾಹಿತಿ ಕೇಳಬೇಕು ಎಂದು ನೋಡಿ.
-
RCBO Full Form: ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ ಮತ್ತು RCCBಗ...
RCBO ಏನನ್ನು ರಕ್ಷಿಸುತ್ತದೆ, markings ಹೇಗೆ ಓದಬೇಕು ಮತ್ತು RCCB ಹಾಗೂ ಪ್ರತ್ಯೇಕ MCBಗಳ ಜೊತೆ ಹೋಲಿಕೆ ಹೇಗಿದೆ ಎಂದು ನೋಡಿ.
RCBO Full Form: ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ ಮತ್ತು RCCBಗ...
RCBO ಏನನ್ನು ರಕ್ಷಿಸುತ್ತದೆ, markings ಹೇಗೆ ಓದಬೇಕು ಮತ್ತು RCCB ಹಾಗೂ ಪ್ರತ್ಯೇಕ MCBಗಳ ಜೊತೆ ಹೋಲಿಕೆ ಹೇಗಿದೆ ಎಂದು ನೋಡಿ.