MOM-C Single Phase Monoblock (Tullu) Pump Starter Panel with Cyclic Timer
MOM-C Single Phase Monoblock (Tullu) Pump Starter Panel with Cyclic Timer
Couldn't load pickup availability
MOM-C Single Phase Monoblock (Tullu) Pump Starter Panel with Cyclic Timer is designed for 0.5–3 HP single phase monoblock (Tullu) pump variants. It combines pump operation controls with dry-run, overload and voltage protection.
VUKAR MOM-C comes from pump control manufacturer Vukar Automation in Rajkot. Compare the listed MOM-C controls with your pump task.
Which application is this model for?
Choose this model for motor protection and timed operation where automatic tank-level control is not required. MOM-C is the base Cyclic Timer and Auto Switch model without MCB, Clock Timer or tank-level control.
What makes MOM-C different?
MOM-C is the straightforward timed-control option: Cyclic Timer and Auto Switch are included, while MCB, Clock Timer, Water Level Indicator and automatic Water Level Controller are not included. It fits installations where the tank is managed separately and the requirement is motor protection plus repeating pump cycles.
MOM-C HP variants and SKUs
| Motor rating | SKU |
|---|---|
| 0.5 HP | MOM-C0 |
| 0.75 HP | MOM-C1 |
| 1 HP | MOM-C2 |
| 1.5 HP | MOM-C3 |
| 2 HP | MOM-C4 |
| 3 HP | MOM-C5 |
Key functions
- Motor monitoring: dual digital display for voltage and current, plus motor-on and fault indications for troubleshooting.
- Motor records: fault counter and total run-time counter to support maintenance tracking.
- Motor protection: overvoltage, undervoltage, overload and dry-run protection; check settings and the water source after a trip.
- Timer control: Cyclic Timer for repeating on/off cycles and Auto-Off Stop Timer for limiting a selected run duration.
- Auto Switch: manages pump operation according to the configured settings when healthy supply returns.
- Restart control: Power-On Auto-Start delay and programmable dry-run retry to manage restart timing after supply or water-source recovery.
- Construction: powder-coated metal enclosure, FRLS internal wiring and a serviceable terminal layout.
Choose the correct HP variant
Options are available for 0.5, 0.75, 1, 1.5, 2 and 3 HP pumps. Match the selected variant to the pump nameplate. Before ordering, confirm the power supply, full-load current, cable size and starter settings with a qualified electrician.
Installation and operating notes
- Install the panel in a dry, ventilated location and provide proper earthing.
- Set voltage, current, dry-run and timer parameters for the connected pump; factory/default values may not suit every installation.
- Use the timer settings for the required pump run and pause periods. This model uses timer-based operation rather than tank-level sensing.
- After a protection trip, identify and correct the cause before restarting the pump.
Warranty, dispatch and support
- 1-year product warranty when purchased from this website.
- Orders are dispatched within 0–1 working day; expected delivery is 1–5 working days from the order date across India.
- Free shipping across India.
- Technical support by WhatsApp or call: +91 63588 96254.
Compare related starter panels
- Compare all single phase monoblock (Tullu) starter panel models
- Compare single phase openwell starter panel models
- View the VUKAR starter-panel comparison and price list
Product images and feature guides
Display and everyday operation

Digital display
View supply voltage and motor current.

Fault display
View fault indications when troubleshooting the pump.

Motor fault counter
Keep track of motor faults.

Motor run-time counter
Track total motor operating time.

Motor ON indication
See when the pump is running.
Protection and control features

Voltage protection
Overvoltage and undervoltage protection for the connected pump.

Overload protection
Overload protection for the connected pump.

Overload protection guide
Check protection settings after a trip.
Timing and automatic control

Auto-off stop timer
Stop the pump after the selected running duration.

Power-on start delay
Configure restart timing after supply recovery.

Inbuilt Auto Switch
Use automatic operation with the configured pump settings.

Cyclic Timer
Run the pump in repeated ON and OFF cycles.

Dry-run restart delay
Use programmable dry-run retry to manage restart timing.

Timer settings guide
Set timer parameters for the connected pump.
Installation and ownership

Product-registration guide

Serviceable internal wiring
FRLS wiring and terminals support inspection and servicing.

Internal components

Powder-coated metal enclosure
Metal cabinet with a powder-coated finish.
Frequently asked questions
Which pump should I select MOM-C for?
Choose the matching 0.5–3 HP variant for a single phase monoblock (Tullu) pump. Verify the pump nameplate, current, wiring and settings before installation.
Is professional installation required?
Yes. A qualified electrician should complete wiring, earthing, protection settings and commissioning.
Does this model automatically control tank filling?
No. This model does not include automatic Water Level Controller operation.
Product videos and selection guidance: MOM-C product videos.
Share
Customers are saying

Great product
Working well
Motor Starter Panel & Protection Devices
View all-
Single Phase Borewell Level Control Panels (BOA) ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Single Phase Borewell Level Control Panels (BOA) options compare ಮಾಡಿ. ಆಯ್ಕೆ...
-
Three Phase Digital Auto Switch for Water Pumps ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Three Phase Digital Auto Switch for Water Pumps options compare ಮಾಡಿ....
-
VUKARನ ಎಲ್ಲಾ Products
ಒಂದೇ listingನಲ್ಲಿ ಪೂರ್ಣ VUKAR catalogue ನೋಡಿ: starter panels, auto switches, water level...
-
Three Phase Borewell DOL Panels with Timer (TPM) ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Three Phase Borewell DOL Panels with Timer (TPM) options compare ಮಾಡಿ....
Blog posts
View all-
Star Delta Starter: ಕೆಲಸ ಮಾಡುವ ವಿಧಾನ, Motor ಅಗತ...
VUKAR AutomationStar-Delta Starting, ಆರು Terminal ಮತ್ತು Voltage ಅಗತ್ಯಗಳು, Transition ಹಂತಗಳು ಹಾಗೂ Starter ಆರಿಸುವ ಮೊದಲು ಬೇಕಾದ ಪರಿಶೀಲನೆಗಳನ್ನು ತಿಳಿಯಿರಿ.
Star Delta Starter: ಕೆಲಸ ಮಾಡುವ ವಿಧಾನ, Motor ಅಗತ...
VUKAR AutomationStar-Delta Starting, ಆರು Terminal ಮತ್ತು Voltage ಅಗತ್ಯಗಳು, Transition ಹಂತಗಳು ಹಾಗೂ Starter ಆರಿಸುವ ಮೊದಲು ಬೇಕಾದ ಪರಿಶೀಲನೆಗಳನ್ನು ತಿಳಿಯಿರಿ.
-
MCB ಪೂರ್ಣ ಹೆಸರು: ಅರ್ಥ, ಕಾರ್ಯ ಮತ್ತು RCCBಯಿಂದ ವ್ಯ...
VUKAR AutomationMCB ಎಂದರೆ Miniature Circuit Breaker. Overload ಮತ್ತು short-circuit protection, ಸಾಧನದ markings ಹಾಗೂ MCBಯು RCCB ಅಥವಾ RCBOಯಿಂದ ಹೇಗೆ ಭಿನ್ನವಾಗಿದೆ ಎಂಬುದನ್ನು ತಿಳಿಯಿರಿ.
MCB ಪೂರ್ಣ ಹೆಸರು: ಅರ್ಥ, ಕಾರ್ಯ ಮತ್ತು RCCBಯಿಂದ ವ್ಯ...
VUKAR AutomationMCB ಎಂದರೆ Miniature Circuit Breaker. Overload ಮತ್ತು short-circuit protection, ಸಾಧನದ markings ಹಾಗೂ MCBಯು RCCB ಅಥವಾ RCBOಯಿಂದ ಹೇಗೆ ಭಿನ್ನವಾಗಿದೆ ಎಂಬುದನ್ನು ತಿಳಿಯಿರಿ.
-
PM Surya Ghar Yojana: ಸಬ್ಸಿಡಿ, ಅರ್ಜಿಯ ಹಂತಗಳು ಮತ...
VUKAR AutomationPM Surya Ghar ನ Rooftop Solar ಸಹಾಯ ತಿಳಿಯಿರಿ, Installation ಬೆಲೆಪಟ್ಟಿಗಳನ್ನು ಹೋಲಿಸಿ ಮತ್ತು ಅಧಿಕೃತ ಅರ್ಜಿ ಪ್ರಕ್ರಿಯೆಗೆ ಸಿದ್ಧರಾಗಿ.
PM Surya Ghar Yojana: ಸಬ್ಸಿಡಿ, ಅರ್ಜಿಯ ಹಂತಗಳು ಮತ...
VUKAR AutomationPM Surya Ghar ನ Rooftop Solar ಸಹಾಯ ತಿಳಿಯಿರಿ, Installation ಬೆಲೆಪಟ್ಟಿಗಳನ್ನು ಹೋಲಿಸಿ ಮತ್ತು ಅಧಿಕೃತ ಅರ್ಜಿ ಪ್ರಕ್ರಿಯೆಗೆ ಸಿದ್ಧರಾಗಿ.
-
Submersible Pump ದುರಸ್ತಿ ವೆಚ್ಚ: ಯಾವ Parts ಮತ್ತು...
Mohit Vekariaಕೇವಲ Workshop ಮೊತ್ತವಲ್ಲ, ಸಂಪೂರ್ಣ Submersible ದುರಸ್ತಿ ಕೆಲಸವನ್ನು ಹೋಲಿಸಿ. ಕೆಲಸ ಅನುಮೋದಿಸುವ ಮೊದಲು Servicing, ಪ್ರಮುಖ Parts, ಹೊರತೆಗೆಯುವಿಕೆ ಮತ್ತು ಮರು-Commission ಮಾಡುವುದನ್ನು ಬೇರ್ಪಡಿಸಿ.
Submersible Pump ದುರಸ್ತಿ ವೆಚ್ಚ: ಯಾವ Parts ಮತ್ತು...
Mohit Vekariaಕೇವಲ Workshop ಮೊತ್ತವಲ್ಲ, ಸಂಪೂರ್ಣ Submersible ದುರಸ್ತಿ ಕೆಲಸವನ್ನು ಹೋಲಿಸಿ. ಕೆಲಸ ಅನುಮೋದಿಸುವ ಮೊದಲು Servicing, ಪ್ರಮುಖ Parts, ಹೊರತೆಗೆಯುವಿಕೆ ಮತ್ತು ಮರು-Commission ಮಾಡುವುದನ್ನು ಬೇರ್ಪಡಿಸಿ.
Blog posts
-
Indian Agricultureಗಾಗಿ 3 Phase Digital Auto Swi...
ಈ guide ಮೂಲಕ exact Three Phase Auto Switchನ documented functions check ಮಾಡಿ. Device ಅನ್ನು motor ಮತ್ತು existing starterಗೆ match ಮಾಡಿ; protection supported functions, settings ಮತ್ತು installation ಮೇಲೆ ಅವಲಂಬಿತವಾಗಿದೆ. Three-Phase Auto...
Indian Agricultureಗಾಗಿ 3 Phase Digital Auto Swi...
ಈ guide ಮೂಲಕ exact Three Phase Auto Switchನ documented functions check ಮಾಡಿ. Device ಅನ್ನು motor ಮತ್ತು existing starterಗೆ match ಮಾಡಿ; protection supported functions, settings ಮತ್ತು installation ಮೇಲೆ ಅವಲಂಬಿತವಾಗಿದೆ. Three-Phase Auto...
-
Borewell Starter Panels: Water Level Control ಮತ...
Water level control ಮತ್ತು motor protection Borewell Pump Starter ನಲ್ಲಿ Water Level Control ಇದ್ದರೆ ಟ್ಯಾಂಕ್ ತುಂಬಿಸುವ ಕೆಲಸ ಸ್ವಯಂಚಾಲಿತವಾಗಬಹುದು, ಆದರೆ Water Level Control ಮತ್ತು ವಿದ್ಯುತ್ ರಕ್ಷಣೆ ಬೇರೆ ಕಾರ್ಯಗಳು. ನಿಜವಾದ Pump, Supply...
Borewell Starter Panels: Water Level Control ಮತ...
Water level control ಮತ್ತು motor protection Borewell Pump Starter ನಲ್ಲಿ Water Level Control ಇದ್ದರೆ ಟ್ಯಾಂಕ್ ತುಂಬಿಸುವ ಕೆಲಸ ಸ್ವಯಂಚಾಲಿತವಾಗಬಹುದು, ಆದರೆ Water Level Control ಮತ್ತು ವಿದ್ಯುತ್ ರಕ್ಷಣೆ ಬೇರೆ ಕಾರ್ಯಗಳು. ನಿಜವಾದ Pump, Supply...