DEV-H2 Single Phase Openwell Water Level Controller
DEV-H2 Single Phase Openwell Water Level Controller
Couldn't load pickup availability
VUKAR DEV-H2 is a single phase water level controller for openwell and monoblock pumps with double float-switch inputs, cyclic timer, monitoring and protection.
Who Should Choose This Model
Choose DEV-H2 for a single phase openwell or monoblock pump that needs double float-switch level control and cyclic-timer operation.
Product and Installation Videos
Monitoring and Control
High-Brightness Dual Digital Display
Shows voltage, current and other pump parameters during operation.

Fault Display Indication
Shows common motor-fault indications to support troubleshooting.

Motor Fault Counter
Records the number of detected motor faults so recurring conditions can be reviewed.

Motor Run-Time Counter
Records cumulative motor running time for maintenance planning.

Motor-On and Fault Indication
Provides visual indication of motor-running and fault status.

Automatic Water Level Controller
Uses the connected float-switch input to start and stop the pump according to tank level.

Water Level Indicator
Shows the tank-level status used by the controller.

Overvoltage and Undervoltage Protection
Stops the pump when supply voltage moves outside the configured range.

Overload and Dry-Run Protection
Stops the motor during detected overload or dry-run conditions to reduce damage risk.

Overload Safety Lockout
Keeps the controller stopped after an overload until a manual reset is completed.

Auto-Off Stop Timer
Stops the pump after the configured running duration.

Protection and Automation
Power-On Auto-Start Timer
Adds a configurable delay before pump start after power returns.

Built-In Auto Switch
Supports automatic pump start when the required supply conditions are available.

Cyclic Timer
Runs repeated ON/OFF cycles according to the configured schedule.

Starting-Torque Timer
Controls the single phase motor-starting sequence through an adjustable timer.

Programmable Dry-Run Restart Timer
Stops the pump on dry run and retries after the configured recovery delay.

Timer Power-Failure Recovery
Restores the programmed timer cycle after a power interruption.

Digital Product Registration
Supports digital registration for product and service records.

Protective Enclosure
Uses a protective enclosure intended to support stable controller operation.

Technical Support
Technical support is available by WhatsApp and call at +91 63588 96254.

Double Cable Float Switch
Includes double cable float-switch inputs for openwell or monoblock tank-level control.

Selection and Installation
Use with a compatible single phase openwell or monoblock pump circuit. Have a qualified electrician connect both float-switch inputs and motor wiring according to the supplied wiring guide.
Before Ordering
Verify motor rating, wiring and sensor configuration. Review the current Shipping Policy, Refund Policy and Contact page.
FAQ
Which application is DEV-H2 for?
Choose DEV-H2 for a single phase openwell or monoblock pump that needs double float-switch level control and cyclic-timer operation.
Does it include a clock timer?
No. This model uses a cyclic timer; compare a clock-timer model for time-of-day scheduling.
How should the float switch be connected?
Follow the supplied wiring guide and use a qualified electrician.
Compare Related Models
Share
Customers are saying

Motor Starter Panel & Protection Devices
View all-
Single Phase Borewell Level Control Panels (BOA) ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Single Phase Borewell Level Control Panels (BOA) options compare ಮಾಡಿ. ಆಯ್ಕೆ...
-
Three Phase Digital Auto Switch for Water Pumps ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Three Phase Digital Auto Switch for Water Pumps options compare ಮಾಡಿ....
-
VUKARನ ಎಲ್ಲಾ Products
ಒಂದೇ listingನಲ್ಲಿ ಪೂರ್ಣ VUKAR catalogue ನೋಡಿ: starter panels, auto switches, water level...
-
Three Phase Borewell DOL Panels with Timer (TPM) ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Three Phase Borewell DOL Panels with Timer (TPM) options compare ಮಾಡಿ....
Blog posts
View all-
VUKAR Motor Starter Fault Codes: FOL, FDR, HIU,...
Mohit VekariaVUKAR FOL, FDR, HIU, LOU ಮತ್ತು SPP: ಅನ್ವಯಿಸುವ products, common manual reset, DEV-Nನ SET → RST exception, auto-clear conditions ಮತ್ತು ಸುರಕ್ಷಿತ ಸಹಾಯ.
VUKAR Motor Starter Fault Codes: FOL, FDR, HIU,...
Mohit VekariaVUKAR FOL, FDR, HIU, LOU ಮತ್ತು SPP: ಅನ್ವಯಿಸುವ products, common manual reset, DEV-Nನ SET → RST exception, auto-clear conditions ಮತ್ತು ಸುರಕ್ಷಿತ ಸಹಾಯ.
-
Submersible Pump Starter Panel: Functions ಮತ್ತು...
Mohit VekariaPanel ಆಯ್ಕೆ ಮಾಡುವ ಅಥವಾ automation ಸೇರಿಸುವ ಮೊದಲು pump starter controls, protection limits ಮತ್ತು model-selection checks ತಿಳಿಯಿರಿ.
Submersible Pump Starter Panel: Functions ಮತ್ತು...
Mohit VekariaPanel ಆಯ್ಕೆ ಮಾಡುವ ಅಥವಾ automation ಸೇರಿಸುವ ಮೊದಲು pump starter controls, protection limits ಮತ್ತು model-selection checks ತಿಳಿಯಿರಿ.
-
Three Phase Digital Motor Starter Panel ಆಯ್ಕೆ ಮ...
Mohit VekariaMotor rating, documented protection, restart behaviour ಮತ್ತು installation requirements ನೋಡಿ three-phase starter panel compare ಮಾಡಿ.
Three Phase Digital Motor Starter Panel ಆಯ್ಕೆ ಮ...
Mohit VekariaMotor rating, documented protection, restart behaviour ಮತ್ತು installation requirements ನೋಡಿ three-phase starter panel compare ಮಾಡಿ.
-
Motor Protection Device: Functions, Limits ಮತ್ತ...
Mohit Vekariaಸರಿಯಾಗಿ ಆಯ್ಕೆಮಾಡಿದ starter panel, detect ಮಾಡಲು ರೂಪಿಸಿ set ಮಾಡಿದ faults ಬಂದಾಗ pump ನಿಲ್ಲಿಸಬಹುದು. ನಿರಂತರ water supply, ಎಲ್ಲಾ motor failures ತಡೆಯುವುದು ಅಥವಾ maintenance ಅಗತ್ಯವಿಲ್ಲ ಎಂಬ guarantee ಇಲ್ಲ. ಸಂಪೂರ್ಣ protection system ಪರಿಶೀಲಿಸಿ...
Motor Protection Device: Functions, Limits ಮತ್ತ...
Mohit Vekariaಸರಿಯಾಗಿ ಆಯ್ಕೆಮಾಡಿದ starter panel, detect ಮಾಡಲು ರೂಪಿಸಿ set ಮಾಡಿದ faults ಬಂದಾಗ pump ನಿಲ್ಲಿಸಬಹುದು. ನಿರಂತರ water supply, ಎಲ್ಲಾ motor failures ತಡೆಯುವುದು ಅಥವಾ maintenance ಅಗತ್ಯವಿಲ್ಲ ಎಂಬ guarantee ಇಲ್ಲ. ಸಂಪೂರ್ಣ protection system ಪರಿಶೀಲಿಸಿ...
Blog posts
-
Indian Agricultureಗಾಗಿ 3 Phase Digital Auto Swi...
ಈ guide ಮೂಲಕ exact Three Phase Auto Switchನ documented functions check ಮಾಡಿ. Device ಅನ್ನು motor ಮತ್ತು existing starterಗೆ match ಮಾಡಿ; protection supported functions, settings ಮತ್ತು installation ಮೇಲೆ ಅವಲಂಬಿತವಾಗಿದೆ. 3 Phase...
Indian Agricultureಗಾಗಿ 3 Phase Digital Auto Swi...
ಈ guide ಮೂಲಕ exact Three Phase Auto Switchನ documented functions check ಮಾಡಿ. Device ಅನ್ನು motor ಮತ್ತು existing starterಗೆ match ಮಾಡಿ; protection supported functions, settings ಮತ್ತು installation ಮೇಲೆ ಅವಲಂಬಿತವಾಗಿದೆ. 3 Phase...
-
Borewell Panelನಲ್ಲಿ Motor Protection ಮತ್ತು Wate...
Water level control ಮತ್ತು motor protection Water level control ಇರುವ borewell pump starter tank ತುಂಬಿಸುವ ಕೆಲಸವನ್ನು automatic ಮಾಡಬಹುದು. ಆದರೆ level control ಮತ್ತು electrical protection ಬೇರೆ functions. Actual pump, supply ಮತ್ತು...
Borewell Panelನಲ್ಲಿ Motor Protection ಮತ್ತು Wate...
Water level control ಮತ್ತು motor protection Water level control ಇರುವ borewell pump starter tank ತುಂಬಿಸುವ ಕೆಲಸವನ್ನು automatic ಮಾಡಬಹುದು. ಆದರೆ level control ಮತ್ತು electrical protection ಬೇರೆ functions. Actual pump, supply ಮತ್ತು...