{"product_id":"single-phase-digital-openwell-borewell-starter-panel-with-motor-safety-motor-auto-off-stop-timer-water-level-indicator-mcb-bom-w","title":"Single Phase Digital Openwell \/ Borewell Starter Panel with Motor Safety, Motor Auto Off \/ Stop Timer, Water Level Indicator \u0026 MCB (BOM-W)","description":"\u003cdiv class=\"vukar-product-copy\" data-model=\"BOM-W\"\u003e\n\u003cp\u003e\u003cstrong\u003eBOM-W\u003c\/strong\u003e is a single phase borewell\/openwell motor starter panel for 0.5–3 HP pumps. Its defining function is water level indicator, auto-off stop timer and inbuilt MCB. Select the exact HP variant only after matching the pump rating and operating current.\u003c\/p\u003e\n\u003ch2\u003eWho should choose BOM-W?\u003c\/h2\u003e\n\u003cp\u003eChoose BOM-W when tank-level indication, timed stopping and an inbuilt MCB are all required in one starter panel.\u003c\/p\u003e\n\u003ch2\u003eModel-specific functions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWater Level Indicator gives visible tank-status information from the connected float switch.\u003c\/li\u003e\n\u003cli\u003eAuto-Off Stop Timer stops the pump after the duration set on the panel.\u003c\/li\u003e\n\u003cli\u003eInbuilt MCB provides short-circuit protection for the panel circuit; cable float switch is included.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eMotor protection and monitoring\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOvervoltage and undervoltage protection disconnects the motor when supply voltage moves outside the configured limits.\u003c\/li\u003e\n\u003cli\u003eOverload and dry-run protection stops the pump when the configured current conditions indicate excess load or loss of water.\u003c\/li\u003e\n\u003cli\u003eOverload Safety Lockout, Power-On Auto-Start Timer and Programmable Dry-Run Auto-Restart Timer support controlled recovery after a fault or power interruption.\u003c\/li\u003e\n\u003cli\u003eMotor ON indication, fault display, fault counter and run-time counter provide operating information on the panel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct feature reference\u003c\/h2\u003e\n\u003cdiv class=\"vukar-feature-images\"\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/Single_Phase_High_brightness_Digital_Display.png?v=1758384191\" alt=\"High brightness dual digital display on a single phase panel\" loading=\"lazy\"\u003e\u003cfigcaption\u003eBOM-W: High brightness dual digital display on a single phase panel\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/Fault_Display_Indication_1db23bc5-e6a6-4517-8939-8977490789b3.png?v=1758384191\" alt=\"Fault display indication showing motor error codes on the panel\" loading=\"lazy\"\u003e\u003cfigcaption\u003eBOM-W: Fault display indication showing motor error codes on the panel\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/Motor_Fault_Counter_a0545f00-dbac-414a-a32f-6de0638c1214.png?v=1758384191\" alt=\"Motor fault counter logging and displaying the number of trips\" loading=\"lazy\"\u003e\u003cfigcaption\u003eBOM-W: Motor fault counter logging and displaying the number of trips\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/Motor_Run_Time_Counter.png?v=1758384191\" alt=\"Motor run time counter logging cumulative pump operating hours\" loading=\"lazy\"\u003e\u003cfigcaption\u003eBOM-W: Motor run time counter logging cumulative pump operating hours\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/Motor_On_Indication.png?v=1758384998\" alt=\"Motor on indication confirming the pump is currently running\" loading=\"lazy\"\u003e\u003cfigcaption\u003eBOM-W: Motor on indication confirming the pump is currently running\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/Water_Level_Indicator_442168d4-0fb8-4751-bd8c-7579551dcff9.png?v=1758384191\" alt=\"Water level indicator giving visual confirmation of tank status\" loading=\"lazy\"\u003e\u003cfigcaption\u003eBOM-W: Water level indicator giving visual confirmation of tank status\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/motor_voltage_protection.png?v=1758384191\" alt=\"Overvoltage and undervoltage protection keeping the motor in safe limits\" loading=\"lazy\"\u003e\u003cfigcaption\u003eBOM-W: Overvoltage and undervoltage protection keeping the motor in safe limits\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/Motor_Dry_Run_Protection.png?v=1758384191\" alt=\"Dry run protection cutting power when the water source runs dry\" loading=\"lazy\"\u003e\u003cfigcaption\u003eBOM-W: Dry run protection cutting power when the water source runs dry\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/Auto_Off_Stop_Timer_3316920b-bbe4-49f2-9afa-a4f408ff67f3.png?v=1758384191\" alt=\"Auto off stop timer switching the motor off after a set duration\" loading=\"lazy\"\u003e\u003cfigcaption\u003eBOM-W: Auto off stop timer switching the motor off after a set duration\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/starter_panel_with_isi_wiring_800d7378-fe73-4465-b043-86500500ab16.png?v=1758384191\" alt=\"Panel internals with ISI marked copper wiring on heavy duty lugs\" loading=\"lazy\"\u003e\u003cfigcaption\u003eBOM-W: Panel internals with ISI marked copper wiring on heavy duty lugs\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/vukar_premium_quality_capacitor.png?v=1758384191\" alt=\"Built in 440 V motor run capacitor for stable starting\" loading=\"lazy\"\u003e\u003cfigcaption\u003eBOM-W: Built in 440 V motor run capacitor for stable starting\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/Starter_panel_with_inbuilt_MCB.png?v=1758384191\" alt=\"Inbuilt MCB giving short circuit protection in the panel\" loading=\"lazy\"\u003e\u003cfigcaption\u003eBOM-W: Inbuilt MCB giving short circuit protection in the panel\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/vukar_powder_coated_metal_enclosure.png?v=1758384192\" alt=\"Powder coated metal enclosure protecting the panel internals\" loading=\"lazy\"\u003e\u003cfigcaption\u003eBOM-W: Powder coated metal enclosure protecting the panel internals\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/starter_with_cable_float_switch.png?v=1758384191\" alt=\"Cable float switch included for automatic tank level sensing\" loading=\"lazy\"\u003e\u003cfigcaption\u003eBOM-W: Cable float switch included for automatic tank level sensing\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003ch2\u003eInstallation and selection\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUse only with a compatible single phase borewell or openwell pump within the selected 0.5–3 HP variant range.\u003c\/li\u003e\n\u003cli\u003eMatch the variant to the pump nameplate HP and current; protection settings must be configured for the actual motor.\u003c\/li\u003e\n\u003cli\u003eInstallation, earthing, capacitor connections and sensor wiring should be completed by a qualified electrician.\u003c\/li\u003e\n\u003cli\u003eTank sensor or float-switch positioning must be tested before automatic operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWarranty, delivery and support\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWarranty: 1 year when purchased from this website.\u003c\/li\u003e\n\u003cli\u003eDispatch: 0–1 working day. Expected delivery: 1–5 working days from the order date across India.\u003c\/li\u003e\n\u003cli\u003eShipping: free across India; no hidden or extra charge stated for the order.\u003c\/li\u003e\n\u003cli\u003eTechnical support: WhatsApp or call \u003ca href=\"tel:+916358896254\"\u003e+91 63588 96254\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eTo order by phone, send your name, address, contact number, PIN code and model to \u003ca href=\"tel:+919512172271\"\u003e+91 95121 72271\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eDoes the panel work with every single phase pump?\u003c\/h3\u003e\n\u003cp\u003eNo. Choose the correct HP\/current variant for the pump nameplate and verify wiring and capacitor requirements before installation.\u003c\/p\u003e\n\u003ch3\u003eDoes BOM-W include automatic tank-level control?\u003c\/h3\u003e\n\u003cp\u003eNo automatic tank-level control is claimed for this model. It includes tank-level indication through the supplied cable float switch.\u003c\/p\u003e\n\u003cdiv class=\"vukar-related-links\"\u003e\n\u003ch2\u003eCompare the VUKAR range\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/gu\/pages\/single-phase-borewell-submersible-pump-starter-panel-comparison\"\u003eCompare single phase borewell starter models\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/gu\/pages\/single-phase-openwell-submersible-starter-panel-comparison\"\u003eCompare single phase openwell starter models\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/gu\/pages\/compare-motor-starter-panel\"\u003eView VUKAR prices and full model comparison\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"VUKAR","offers":[{"title":"0.5 HP \/ Auto Off \/ Stop Timer","offer_id":50462486528306,"sku":"BOM-W0","price":4049.0,"currency_code":"INR","in_stock":true},{"title":"0.75 HP \/ Auto Off \/ Stop Timer","offer_id":50462486561074,"sku":"BOM-W1","price":4099.0,"currency_code":"INR","in_stock":true},{"title":"1 HP \/ Auto Off \/ Stop Timer","offer_id":50462486593842,"sku":"BOM-W2","price":4149.0,"currency_code":"INR","in_stock":true},{"title":"1.5 HP \/ Auto Off \/ Stop Timer","offer_id":50462486626610,"sku":"BOM-W3","price":4199.0,"currency_code":"INR","in_stock":true},{"title":"2 HP \/ Auto Off \/ Stop Timer","offer_id":50462486659378,"sku":"BOM-W4","price":4499.0,"currency_code":"INR","in_stock":true},{"title":"3 HP \/ Auto Off \/ Stop Timer","offer_id":50462486692146,"sku":"BOM-W5","price":7199.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/SinglePhaseStarterPanelwithWaterLevelIndicator_DryRunProtection_MCB.png?v=1760334661","url":"https:\/\/submersibleshop.com\/gu\/products\/single-phase-digital-openwell-borewell-starter-panel-with-motor-safety-motor-auto-off-stop-timer-water-level-indicator-mcb-bom-w","provider":"VUKAR","version":"1.0","type":"link"}