{"title":"Single Phase Digital Meter with Motor Protection \u0026 Cyclic Timer","description":"\u003cp\u003eThe best single phase digital meter from a trusted Indian manufacturer. This advanced pump controller is a smart buy for its built-in cyclic timer and comprehensive motor protection, offering precise and reliable operation.\u003c\/p\u003e\u003cdiv class=\"vukar-related-links\"\u003e\n\u003ch3\u003eCompare VUKAR models before you buy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/gu\/pages\/digital-meter-comparison\"\u003eCompare all 23 motor protection devices, auto switches and digital meters\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/gu\/pages\/single-phase-borewell-submersible-pump-starter-panel-comparison\"\u003eCompare all 9 single phase borewell starter panel models\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/gu\/pages\/compare-motor-starter-panel\"\u003eVUKAR pricelist and full model comparison\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","products":[{"product_id":"single-phase-digital-meter-with-motor-protection-cyclic-timer-dm-sp-cyc-96","title":"DM-SP-CYC-96 Single Phase Motor Protection with Cyclic Timer","description":"\u003cp\u003e\u003cstrong\u003eDM-SP-CYC-96 single phase motor protection device\u003c\/strong\u003e is designed for pump control circuits that need motor protection with cyclic pump scheduling. It monitors voltage\/current and stops the motor-control output when configured electrical faults are detected.\u003c\/p\u003e\n\u003ch2\u003eWhen should you choose this model?\u003c\/h2\u003e\u003cp\u003eChoose DM-SP-CYC-96 when you need motor protection without tank-level automation plus repeated ON\/OFF cyclic scheduling. Confirm the phase, wiring, control circuit and motor rating before installation.\u003c\/p\u003e\n\u003ch2\u003eCore functions\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eVoltage\/current monitoring and fault indication\u003c\/li\u003e\n\u003cli\u003eOvervoltage, undervoltage, overload and dry-run protection\u003c\/li\u003e\n\u003cli\u003eCyclic Timer, Auto-Off Stop Timer and power-on start delay\u003c\/li\u003e\n\u003cli\u003eFault counter, total run-time counter and automatic\/manual modes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and setup\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eInstall with a compatible pump starter or contactor control circuit.\u003c\/li\u003e\n\u003cli\u003eUse a qualified electrician to verify wiring, earthing and the motor rating.\u003c\/li\u003e\n\u003cli\u003eSet voltage, current, dry-run and timer parameters for the connected pump.\u003c\/li\u003e\n\u003cli\u003eAfter a trip, identify and correct the fault before restart.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWarranty, dispatch and support\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e1-year product warranty when purchased from this website.\u003c\/li\u003e\n\u003cli\u003eOrders are dispatched within 0–1 working day; expected delivery is 1–5 working days from the order date across India.\u003c\/li\u003e\n\u003cli\u003eFree shipping across India.\u003c\/li\u003e\n\u003cli\u003eTechnical support by WhatsApp or call: +91 63588 96254.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompare before buying\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/gu\/pages\/digital-meter-comparison\"\u003eCompare motor protection devices and digital meters\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/gu\/pages\/single-phase-borewell-submersible-pump-starter-panel-comparison\"\u003eCompare single phase starter panels\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/gu\/pages\/compare-motor-starter-panel\"\u003eView the VUKAR model and price comparison\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct feature guide\u003c\/h2\u003e\n\u003ch3\u003eDual digital display\u003c\/h3\u003e\n\u003cp\u003eShows single phase voltage and current during operation.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/Single_Phase_High_brightness_Digital_Display.png?v=1758384191\" alt=\"Dual digital display – DM-SP-CYC-96\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003ch3\u003eFault indication\u003c\/h3\u003e\n\u003cp\u003eDisplays detected motor faults to support troubleshooting.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/Fault_Display_Indication_1db23bc5-e6a6-4517-8939-8977490789b3.png?v=1758384191\" alt=\"Fault indication – DM-SP-CYC-96\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003ch3\u003eMotor fault counter\u003c\/h3\u003e\n\u003cp\u003eRecords the number of motor-fault events.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/Motor_Fault_Counter_a0545f00-dbac-414a-a32f-6de0638c1214.png?v=1758384191\" alt=\"Motor fault counter – DM-SP-CYC-96\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003ch3\u003eMotor run-time counter\u003c\/h3\u003e\n\u003cp\u003eRecords cumulative motor running time for maintenance reference.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/Motor_Run_Time_Counter.png?v=1758384191\" alt=\"Motor run-time counter – DM-SP-CYC-96\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003ch3\u003eMotor status indication\u003c\/h3\u003e\n\u003cp\u003eShows motor ON and fault status.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/Motor_On_Indication.png?v=1758384998\" alt=\"Motor status indication – DM-SP-CYC-96\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003ch3\u003eVoltage protection\u003c\/h3\u003e\n\u003cp\u003eStops the control output when voltage moves outside configured limits.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/motor_voltage_protection.png?v=1758384191\" alt=\"Voltage protection – DM-SP-CYC-96\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003ch3\u003eOverload and dry-run protection\u003c\/h3\u003e\n\u003cp\u003eStops the motor-control output during configured overload or dry-run conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/motor_overload_protection.png?v=1758384191\" alt=\"Overload and dry-run protection – DM-SP-CYC-96\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003ch3\u003eOverload safety lockout\u003c\/h3\u003e\n\u003cp\u003eKeeps the control output stopped after an overload until reset.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/Overload_Safety_Lockout_67b7ed01-1190-4e0e-a5f4-9ed37057ebbe.png?v=1758384191\" alt=\"Overload safety lockout – DM-SP-CYC-96\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003ch3\u003eAuto-off stop timer\u003c\/h3\u003e\n\u003cp\u003eStops the pump after the configured running duration.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/Auto_Off_Stop_Timer_3316920b-bbe4-49f2-9afa-a4f408ff67f3.png?v=1758384191\" alt=\"Auto-off stop timer – DM-SP-CYC-96\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003ch3\u003ePower-on start delay\u003c\/h3\u003e\n\u003cp\u003eAdds a configured delay before restart after power returns.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/Power_On_Auto_Start_Timer_a45d3c20-c619-4678-a77f-29fcca081040.png?v=1758384191\" alt=\"Power-on start delay – DM-SP-CYC-96\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003ch3\u003eBuilt-in auto switch\u003c\/h3\u003e\n\u003cp\u003eProvides automatic control when the configured supply conditions are healthy.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/Inbuilt_Auto_Switch_a75f5e45-a46b-4485-a459-6c8a87ebd35a.png?v=1758384192\" alt=\"Built-in auto switch – DM-SP-CYC-96\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003ch3\u003eCyclic timer\u003c\/h3\u003e\n\u003cp\u003eRuns repeated ON\/OFF cycles according to configured timings.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/Cyclic_Timer_5b09a04c-925a-4df6-88f7-8146742cc8e0.png?v=1758384191\" alt=\"Cyclic timer – DM-SP-CYC-96\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003ch3\u003eStarting-torque timing\u003c\/h3\u003e\n\u003cp\u003eControls the configured starting sequence on supported single phase installations.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/Auto_Adjustable_Starting_Torque_Timer_9decd970-62b0-41e7-8a9f-cc537350f847.png?v=1758384191\" alt=\"Starting-torque timing – DM-SP-CYC-96\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003ch3\u003eDry-run restart timer\u003c\/h3\u003e\n\u003cp\u003eRetries after the configured recovery delay following a dry-run stop.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/Programmable_Auto_Restart_Dry_Run_Timer_4d7a1b59-e166-456b-8e18-8807b255e500.png?v=1758384191\" alt=\"Dry-run restart timer – DM-SP-CYC-96\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003ch3\u003eTimer power-failure recovery\u003c\/h3\u003e\n\u003cp\u003eRestores the configured timer cycle after a power interruption.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/Timer_with_Power_Failure_Recovery_39ac9033-e6e7-4122-bf51-6d7c701aab71.png?v=1758384191\" alt=\"Timer power-failure recovery – DM-SP-CYC-96\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003ch3\u003eDigital registration and operating modes\u003c\/h3\u003e\n\u003cp\u003eSupports digital product registration and automatic\/manual operation modes.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/Digital_Warranty_Registration_8914301a-c38d-46ba-b9a3-18e4ecd34d04.png?v=1758384191\" alt=\"Digital registration and operating modes – DM-SP-CYC-96\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical support\u003c\/h3\u003e\n\u003cp\u003eWhatsApp and call support is available at +91 63588 96254.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/100_TECHNICAL_SUPPORT_d0eda494-8bbc-45b4-ae81-82fc9ae1f883.png?v=1758384191\" alt=\"Technical support – DM-SP-CYC-96\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eIs this a complete motor starter?\u003c\/h3\u003e\u003cp\u003eThis is a Motor Protection Device. Install it with a compatible starter or contactor control circuit.\u003c\/p\u003e\u003ch3\u003eAre the same settings suitable for every pump?\u003c\/h3\u003e\u003cp\u003eNo. A qualified electrician should set the parameters for the motor nameplate, supply and installation.\u003c\/p\u003e","brand":"VUKAR","offers":[{"title":"Default Title","offer_id":50411202117938,"sku":"DM-SP-CYC-96","price":1549.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/9129\/0418\/files\/SinglePhaseMPD.png?v=1760334874"}],"url":"https:\/\/submersibleshop.com\/gu\/collections\/single-phase-digital-motor-protection-cyclic-timer.oembed","provider":"VUKAR","version":"1.0","type":"link"}